5104-Hillsboro Avenue North   New Hope, MN 55428
763-531-2222








Temperature, Dewpoint & Humidity Equipment
Ametek
Dry Block Temperature Calibrator
Martel Electronics
TC-100 Thermocouple Calibrator
PTC-8001 High Accuracy Temperature Calibrator Smart Transmitter Compatible
PTC-9002 Precision Temperature Calibrator with Simultaneous mA Input Capability
Tuff-Tools - T120/T130 Single Function Thermocouple & RTD Calibrators
T/C Cable Kit
TP-KIT Probe Kit
MycroSensor
343 Smart Temperature Transmitter
344 Temperature Sensors
Palmer Instruments
Sanitary Bimetal Thermometer
Siemens
Temperature Transmitter
SOR
Temperature Switch and Temperature Transmitter
TelTru
Thermometers Bimetal Dial
Weiss
Mercury-in-Glass Thermometers

Mueller Temperature, Dew Point and Humidity Equipment Supplier Listing

Dry Block Temperature Calibrator
Jofra ATC Dry Block Temperature Calibrator
Ametek’s Jofra ATC Dry Block Temperature Calibrators offer the accuracy of laboratory calibrators in a portable format.Jofra ATC Dry Block Temperature Calibrator ATC dry block calibrators perform fully automatic calibration routines without the use an external computer. All ATC dry block calibrators can upload/download with computers via an RS232 serial port.

The ATC-155 model uses Peltier elements with “multi-stage-technology” that improve the efficiency and service life of the heating/cooling block. The ATC-320 and ATC-650 models have a dual zone heating block. This new design provides superior temperature homogeneity throughout the heating/cooling block. The performance of this new design is equivalent to a liquid temperature bath.

Accuracy and Stability Ratings
Model ATC-155 Model ATC-320 Model ATC-650
Model A Model B Model A Model B Model A Model B
Accuracy ±0.19°C (±0.34°F) ±0.04°C (±0.07°F) ±0.26°C (±0.47°F) ±0.07°C (±0.13°F) ±0.39°C (±0.70°F) ±0.11°C (±0.2°F)
Stability ±0.02°C (±0.036°F) ±0.03°C (±0.054°F)


Temperature Ranges
Model ATC-155: –24° to 155°C (-11° to 311°F)
Model ATC-320: 50° to 320°C (122° to 608°F)
Model ATC-650: 50° to 650°C (122° to 1202°F)

Jofra ITC Dry Block Temperature Calibrator
Ametek offers ITC Dry Block Temperature Calibrators as a mid-range product. Supplied at a reasonable cost, ITC dry block calibratorsJofra ITC Dry Block Temperature Calibrators offer good accuracy and performance. ITC calibrators feature a rugged industrial construction and are easy-to-use and portable. Additionally, ITC calibrators use a state-of-the-art dual zone heating block, which in combination with MVI circuitry ensures stable temperatures even when the mains supply is unstable. All ITC models come equipped with an RS-232 serial port to enable uploading/downloading with computers.

Accuracy and Stability Ratings
Model ITC-155 Model ITC-320 Model ITC-650
Accuracy ±0.25°C (±0.45°F) ±0.3°C (±0.54°F) ±0.5°C (±0.9°F)
Stability ±0.03°C (±0.05°F) ±0.04°C (±0.07°F)


Temperature Ranges
Model ITC-155: -23° to 155°C (-9° to 311°F)

Model ITC-320: 33° to 320°C (91° to 608°F)

Model ITC-650: 33° to 650°C (91° to 1202°F)



TC-100 Thermocouple Calibrator
The Martel Electronics TC-100 Thermocouple Calibrator provides high accuracy source and measurement of ten common thermocouples, as well as mV. The TC-100's accuracy of ±0.3°C for Type J T/Cs includes all errors, at resolutions of ±0.01°C or °F in measure mode and ±0.1°C or °F in source mode.

Features
  • High accuracy - ±0.3°C
  • Ten common T/C types plus mV
  • Accepts both T/C mini-plug and bare T/C wires
  • Martel TC-100 Thermocouple Calibrator
  • Simple decade control of output
  • Three setpoints for each T/C type
  • Minimum and maximum recall in measure mode
  • Input protection to 240 VAC
Specifications
    Output Voltage:
  • Range: -10 to +75.000 mV
  • Resolution: 1 µV
  • Accuracy: ±0.007 % of reading, ±10 µV
  • Output Impedance: &Mac178;1 Ohm

  • Input Voltage:
  • Range: -10 to +75.000 mV
  • Resolution: 1 µV
  • Accuracy: ±0.007 % of reading, ±10 µV
  • Output Impedance: Input Impedance > 1 MegOhm

  • Thermocouple Source/Measure:
  • Types: J, K, T, E, R, S, B, L, U, C
  • Range: mV
  • Resolution
    • Source: ±0.1°C or °F
    • Measure ±0.01°C or °F

PTC-8001 High Accuracy Temperature Calibrator "Smart" Transmitter Compatible
The Martel PTC-8001 Precision Temperature Calibrator combines the most widely used thermocouples and RTDs in one device. The PTC-8801 is especially useful for calibrating “smart” or pulsed RTD transmitters.

Features
  • High accuracy ±0.4°C J T/C and ±0.3°C 4W PT385 RTD all errors included
  • 10 T/C types and 8 RTD types including PT 385 (1000 ohm) and cu (10 ohm)
  • Direct keyboard entry or scroll control of output
  • Nema 4 rated case, rugged design
  • RTD simulation works with all pulsed (smart) transmitters
  • YSI 400 series thermistor range for medical applications
  • Martel PTC-8001 High Accuracy Temperature Calibrator
  • Standard mini-plug or banana jack connections for T/C
  • Store up to nine setpoints for each output function
  • RS232 Interface
Specifications
  • T/C ranges: J, K, T, E, R, S, N, B, L, U including – 10 to 70 mV range
  • RTD ranges: Pt 385 (100, 200, 500, 1000 ohms); Pt 392, JIS, Ni 120, CU10, YSI 400
  • Ohms ranges: 0 to 400.00 and 400.0 to 4000.0
  • Accuracy:
    • T/C Type J: ±.3°C ±10
    • V (±0.6°C total error)
    • RTD PT100: ±.1°C ±.075 (±0.3°C total error)
    • Ohms (400): ±0.1
    • Ohms (4000): ±1.0
  • RTD IEX-range: 0.01 mA to 3 mA
  • RTD frequency response: 10 mS – works with all pulsed XMTR’s
  • Operating temperature: -10°C to 50°C

PTC-9002 Precision Temperature Calibrator with Simultaneous mA Input Capability
The Martel PTC-9002 is a full function thermocouple/RTD calibrator combined with the ability to simultaneously read and display a 4 to 20 mA current loop. The PTC-9002 features 0.5°C accuracy on the most commonly used T/C and RTD ranges. Up to nine setpoints can be stored in non-volatile memory for each of the seven ranges.

Features
  • High accuracy on 4 T/C and 3 RTD ranges
  • Direct keyboard entry of data
  • 63 point calibration memory
  • Martel PTC-9002 Precision Temperature Calibrator with Simultaneous mA Input Capability
  • Simultaneous display of temperature output and 4-20 mA input
  • Built-in 24 volt loop power supply
Specifications
  • Input/Output Ranges
    • T/C: J, K, T, E
    • RTD: Pt 392, Pt 385, Ni 120
    • mA: 0 to 24.000
  • Accuracy: ±.5°C ±1 LSD; .05% of F.S. for mA
  • Cold junction accuracy: ±.2°C
  • Input z (T/C Read): 1M typical
  • Output current (T/C Source): ±10 mA
  • Excitation current (RTD Read): 2.0 mA typical
  • Excitation current input (RTD Source): 0.2 to 3 mA
  • Stability: ±0.005%/°C of FS reading
  • Operating temperature: 32 to 122°F / 0 to 50°C

Tuff-Tools - T120/T130 Single Function Thermocouple & RTD Calibrators
Martel Tuff-Tools - T120/T130 Single Function Thermocouple & RTD Calibrators Martel's Tuff-Tools line of calibrators is designed to give the technician laboratory grade accuracy in a family of rugged, easy to use instruments.

Features
  • High accuracy/source and read capability
  • Rugged, dust tight, water resistant case
  • Easy to read super-twist LCD
  • Intuitive controls make operation easy even for infrequent users
  • Powered by a common 9 vbolt battery

T/C Cable Kit
Martel T/C Cable KitMartel's T/C Cable Kit is ideal for use with MC-1000, PTC-8001 and T120 calibrators. All cables are terminated with a standard mini-connector on one end and bare leads on the other.

  • Type J T/C cable
  • Type T T/C cable
  • Type K T/C cable
  • Type E T/C cable

TP-KIT Probe Kit
Martel TP-KIT Probe KitMartel offers a variety of temperature probe configurations for use with Martel temperature meters and calibrators. All are Type-K, and feature ±2.2°C/±0.75% or ±3.9°F/±0.75% accuracy.

343 Smart Temperature Transmitter
MycroSensor's 343 Smart Temperature Transmitter uses microprocessor-based electronics and temperature measurement circuity in a small cost-effective package. The 343 accepts a wide range of input types and ranges.MycroSensor 343 Smart Temperature Transmitter
  • High accuracy usually 0.05% of reading, guarantees process control integrity
  • HART communications allows quick easy configuration, saving valuable time and money
  • Microprocessor based two-wire transmitter with automatic cold-junction compensation ensure accurate, reliable performance over a wide operating range
Performance Specifications
  • Digital input accuracy: ±0.05% of the equivalent millivolt or OHM reading
  • Cold junction measurement accuracy: ±0.5°C (±0.9°F)
  • D/A output conversion accuracy: ±0.05% of span
  • Total accuracy: [(Input Accuracy)2 + (Cold Junction Accuracy)2 + (D/A Accuracy)2]
  • Ambient temperature range
    • Electronics: -40° to 85°C (-40° ti 185°F)
    • Display: -20° to 70°C (-4° ti 158°F)
  • Stability: less than 0.05% of reading ±3.6 mA for 12 months
  • Power Supply Effect: ±0.005% of span per volt
  • EMI/RFI Susceptibility: less than 0.5% of reading at 10V/m, 20KHz - 1000MHz

344T Temperature Sensors
MycroSensor's 344T Temperature Sensors (thermocouple and RTD assemblies) consist of four basic components: a connection head, an extension, a sensing element, and a thermowell.
Thermal Element Calibration Tolerance
Sensor Type Sensor Range
°F        °C
Calibration
°F
Tolerance*
°C
Materials of Construction
J 32 to 1,400 0 to 760 ±4.0 2.22 Iron, Constantan
K 32 to 2,300 0 to 1260 ±4.0 2.22 Chromel, Alumel
T 32 to 700 0 to 682 ±1.8 1.00 Copper, Constantan
E 32 to 1,600 0 to 871 ±3.0 1.67 Chromel, Constantan
R 32 to 2,700 0 to 1482 ±2.7 1.50 10% Platinum/Rhodium, Platinum
S 32 to 2,300 0 to 1482 ±2.7 1.50 13% Platinum/Rhodium, Platinum
N 32 to 2,300 0 to 1260 ±4.0 2.22 Nisil
B 1600 to 3,100 871 to 1704 ±3.0 1.67 30% Pt/Rhodium, 6% Pt/Rhodium
RTD -58 to 932 -50 to 500 ±0.1 OHMs @ 32°F 100 OHMs Pt, Alpha=0.00385 OHMs/°C


Sanitary Bimetal Thermometer
Palmer ThermometersPalmer Instruments manufactures the first bimetal thermometer to meet 3A sanitary standard 09-09. The thermometer responds faster than mercury-in-glass thermometers and eliminates the need for a thermowell because it is installed directly into the process. The thermometer uses replaceable thermometer cartridges. The replacement element comes precalibrated and ready for installation. This can reduce your thermometer replacement costs.

Palmer Sanitary Bimetal Thermometer come with a one-year warranty and free lifetime recalibration service.

Standard Equipment
Form: Back connected or all angle

Case: Highly polished type 304 stainless steel 3" or 5" Dial. Hermetically sealed. Heavy, heat resistant gasket seals out moisture and prevents icing and freeze-up of the helix

Stem: Type 304 stainless steel 5/16" diameter for extra strength

Stem Length: Same immersion as a sanitary thermowell, 2-½" or 4-½"

Fitting: One piece solid barstock, 3A15 sanitary fitting 1-½" or 2" Tri Clamp

Dial Face: Black lines and numbers on white background. Black pointer. Linear scale. Anti-parallax design

Crystal: Plexiglass

Calibration: Adjustable pointer which permits setting for zero calibration error at any desired temperature within the range of the thermometer

Accuracy: Within one scale division up to ½°F meeting PMO's standard. Ambient temperature changes at the case will not affect accuracy

Element: Replaceable bimetallic element design

Over Range Protection: Temporary swings up to 50% of range will not affect thermometer
Optional: 3" Tri-Clamp, 316 stainless steel stem and Tri-Clamp.


Temperature Transmitters
Sitrans T Transmitters
All Sitrans T transmitters convert signals from...
  • Thermometers
  • Resistance-based sensors
  • Thermocouples
  • Voltages
    into load independent direct current corresponding to the sensor characteristic.
    Sitrans TF Transmitters
    Sitrans TF Transmitters Siemens field transmitters for the rugged industrial environment with IP 65 degree protection

    Sitrans TF Transmitter Features
    Communication capability: Hart protocol V 5.7. Parameterization can be accomplished with a personal computer or Hart hand-held communicator.

    A personal computer is used for parameterization for the programmable Sitrans TF

    Sitrans TF transmitters are available as both “non-incendive protection” transmitters for potentially explosive atmospheres (zone 2) and as “intrinsically-safe” transmitters for potentially explosive atmospheres (zone 1).

    Sitrans TK/TK-H
    Sitrans TK /TK-H Transmitters Siemens Sitrans TK / TK-H is a convenient head-mounted transmitter small enough to fit a type B connection head. Installation in place of the clamping stone means that you save the compensation cables for thermocouples.

    Sitrans TK / TK-H Transmitter Features
    Operating temperatures: -40° to 85°C. (Ex-approval).

    Electrical isolation to 500V AC, separate test terminals for output signals.

    Communication capability: Hart protocol V 5.7. Parameterization can be accomplished with a personal computer or Hart hand-held communicator.

    A personal computer is used for parameterization for the programmable Sitrans TK

    Sitrans TK/TK-H transmitters are available as both “non-incendive protection” transmitters for potentially explosive atmospheres (zone 2) and as “intrinsically-safe” transmitters for potentially explosive atmospheres (zone 1).

    Sitrans T3K PA Transmitters
    Sitrans T3K PA Transmitters Siemens Sitrans T3K PA transmitters have bus connection according to DIN 61 158-2 and EN 50 170, part 4. Same as the TK, a Sitrans T3K PA is a head-mounted transmitter small enough to fit a type B connection head.

    Sitrans T3K PA Transmitter Features
    Data: Measured values with status as a quality specification and other parameters – are provided on PROFIBUS-PA

    Bus connection according to DIN 61 158-2 and EN 50 170, part 4.

    Sitrans T3K PA transmitters are available as both “non-incendive protection” transmitters for potentially explosive atmospheres (zone 2) and as “intrinsically-safe” transmitters for potentially explosive atmospheres (zone 1).

    Specification Sheets (pdf format)

    Temperature Switch and Temperature Transmitter
    SOR Temperature Switch
    SOR Weather Proof Temperature Switch
    Weather Proof Design

  • Direct or remote mount
  • Ranges: –50° to 1000°F
  • Set point adjustment with calibrated scale
  • CSA Approved, CE Marked
  • SOR Weather Proof Terminal Blocks Temperature Switch
    Weather Proof, Terminal Block Connections

  • Direct or remote mount
  • Terminal block connections
  • Ranges: -50° to 1000° F
  • Set point adjustment with calibrated scale
  • CSA Approved, CE Marked
  • SOR Explosion Proof Temperature Switch
    Explosion Proof

  • Direct or remote mount
  • Ranges: –50° to 1000°F
  • Set point adjustment with calibrated scale
  • UL: Class I, Group C, Div. 1 (as an outlet box)
  • SOR Explosion Proof UL/CSA/CENELEC Approved Temperature Switch
    Explosion Proof, UL/CSA/CENELEC Approved

  • Direct or remote mount
  • Terminal block connections
  • Ranges: –50° to 1000°F
  • Set point adjustment with calibrated scale
  • Set point adjustment without declassification of hazardous area
  • UL/CSA: Class I, Group B, Div. 1; BASEEFA: EEx d IIC T6
  • SOR Big Hermet - Explosion Proof, Hermetically Sealed Temperature Switch
    Big Hermet - Explosion Proof, Hermetically Sealed

  • Direct or remote mount
  • Hermetically sealed snap switch(es)
  • Ranges: –50° to 1000°F
  • Set point adjustment with calibrated scale
  • Set point adjustment without declassification of hazardous area
  • UL/CSA: Class I, Group A, Div. 1; DEMKO: EEx m II; SAA: Ex s IIC T6
  • SOR Mini Hermet - Explosion Proof, Hermetically Sealed Temperature Switch
    Mini Hermet - Explosion Proof, Hermetically Sealed

  • Direct or remote mount
  • Hermetically sealed snap switch(es)
  • Ranges: –50° to 1000°F
  • Set point adjustment without declassification of hazardous area
  • UL/CSA: Class I, Group A, Div. 1; DEMKO: EEx m II; SAA: Ex s IIC T6 or BASEEFA: EEx d IIC T6
  • SOR Temperature Transmitter
    SOR Mini Hermet - Explosion Proof, Adjustable Temperature Switch
    Mini Hermet - Explosion Proof, Adjustable

  • Direct or remote mounted RTD designs
  • Hermetically sealed snap switch(es)
  • Calibration without declassification of hazardous area
  • Hermetically sealed electrical connection and zero/span adjustments
  • Ranges: - 150 to 1000°F with 5:1 turndown
  • CSA: Class I, Group A, Div. 1, EXPL/IS


  • Bimetal Thermometers

    TelTru manufactures its market-leading bimetal thermometers at its Rochester NY facility. TelTru sets the bimetal thermometer standard for workmanship quality and accuracy. The use of thermowells in conjunction with bimetal thermometers is recommended for pressure, corrosive fluids, and high velocity applications.

    Standard Specifications
  • ±1% full span accuracy
  • All-welded 304 stainless steel construction
  • Dial sizes of 1", 1-3/8", 1-3/4", 2", 3", 4", 5"
  • Hermetically sealed
  • Quick and easy to recalibrate
  • NPT and BSP connections
  • Over-range protection
  • Stem lengths to 120"
  • Standard stem diameters: .150", .250" and .375"
    (Other stem diameters available)
  • TelTru Bimetal Thermometers

    Options
  • 316 stainless steel wetted parts available
  • Silicone filled available
  • Union connection available
  • Custom configurations









  • Mercury-in-Glass Temperature
    Vari-Angle Thermometers
    Vari-Angle Thermometers Weiss Vari-angle thermometers are constructed with a strong and impact resistant polyester. The rugged construction makes the thermometer a perfect fit for industrial applications, including:
  • Process piping
  • Tanks
  • Building piping
  • Boilers
  • Air ducts


    Features
    Sizes: 7’’ and 9’’

    Temperature range: 0 – 750°F (actual range depends on model)

    Case: Modern V-shape design. Glass front firmly protected against rattles by spring action.

    Stem (31/2" stems and ranges to 300° F): Die cast Zamac alloy
    Stem (above 300° F): Bulb chamber aluminum alloy with copper plated steel stem extension


    6’’ Industrial Thermometers
    6'' Industrial Thermometers Weiss 6" Navay Class Thermometers have excellent readability. The thermometers feature a compact design and rugged construction. The red-reading mercury-in-glass tube maintains accuracy despite vibrations and shock. Applications include:
  • Chilled and hot water lines
  • Small piping networks
  • Equipment operating under continuous vibrating conditions.

    Features
    Sizes: 6’’

    Temperature range:0 to 750°F

    Case: V-shaped polyester case. Wide-angle construction allows full scale width for easy reading.

    Stem: Standard fittings of all brass construction. Standard dual threaded socket for 1/2" and 3/4" NPT.



















  • Home |  Product Catalog |  Company Info |  Market Info |  Career Opportunities |  Contact Us |  Help | User Agreement